Showing results: 16 - 21 of 21 items found.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Standard Capacitors

    1408 Series - IET Labs

    Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.

  • Insulating Oil Dielectric Loss Tester

    HDLT - Hention Electrical Equipment Co., Ltd.

    This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • Tan Delta Test System

    Himalayal Corporation Limited

    Precision measuring bridge is designed for determining the capacitance and dielectric dissipation factor of liquid and solid insulants, cables, capacitors, line transformers, generators, motors, bushings etc. Furthermore it can also be used for power loss measurement on shunt reactors or similar apparatus. This system is suitable for both low and high voltage measurement at line frequency. Measurement reports can be printed. This measuring equipment has been specially developed to maximise efficiency in production and quality control environments. Its outstanding accuracy also makes it suitable for laboratory and research applications.

Get Help